Table 3.

Solubility of various radionuclides from simulated fallout particles (from LeRoy et al., 1966).

Particle characteristicsa used in the study Soluble fraction leached out in 0.1 N HCl (or 0.1 N NaOH)

85Sr 134Cs 133Ba
Local fallout simulated particles: 0.06 0.01 0.05
 Microspheres of fabricated glass particles containing carrier-free tracers, where 10% of activity could be leached out in dilute HCl (0.08) (0.05) (0.07)
Distant location fallout simulated particles: 0.72 0.38 0.91
 Fabricated particles containing carrier tracers, Sr and Ba in oxide form and Cs as silicate. The mix was calcined at 1000° C, 50-100% of activity could be leached out in dilute HCl (0.15) (0.12) (0.23)
a

particle size ranged from 30-40 μm and particle specific activity was about 1.85 MBq per gram.