Skip to main content
. 2010 Apr 23;54(4):459–472. doi: 10.1093/annhyg/meq027

Table 6.

Internal consistency of predicted intensities

Solvent scorea No. scenarios (%)b Measurement data
No. scenarios with data No. reported levels Median (p.p.m.) Mean (p.p.m.)
Methylene chloride
    1: <2 p.p.m. 85 (44) 6 20 1.8 6.5
    2: 2 to <20 p.p.m. 77 (40) 37 726 16 21
    3: 20 to <200 p.p.m. 30 (16) 22 526 47 66
    4: 200 to <2000 p.p.m. 0 (0) 0 0
    5: ≥2000 p.p.m. 0 (0) 0 0
    Overall 192
1,1,1-trichloroethane
    1: <0.5 p.p.m. 197 (46) 22 191 0.43 5.0
    2: 0.5 to <5 p.p.m. 142 (33) 29 622 6.7 22
    3: 5 to <50 p.p.m. 81 (19) 15 116 52 51
    4: 50 to <500 p.p.m. 12 (3) 4 18 110 96
    5: ≥500 p.p.m. 0 (0) 0 0
    Overall 432
Trichloroethylene
    1: <0.3 p.p.m. 2 (<1) 0 0
    2: 0.3 to <3 p.p.m. 55 (11) 18 118 1.7 2.8
    3: 3 to <30 p.p.m. 184 (38) 24 239 16 23
    4: 30 to <300 p.p.m. 184 (38) 15 127 51 58
    5: ≥300 p.p.m. 55 (11) 0 0
    Overall 480
a

Cutpoints determining exposure intensity scores were based on solvent SVPs (see text for additional details).

b

The number of scenario–decades was solvent specific and dependent on the variables in the final models.