Skip to main content
. Author manuscript; available in PMC: 2011 Jul 15.
Published in final edited form as: Anal Chem. 2010 Jul 15;82(14):6104–6114. doi: 10.1021/ac100810e

Table 1.

Summary of cross-validation results of conventional and DCC calibration models applied on the human volunteer data (Sec.-4.2).

Volunteer No. of data points DCC Model Conventional Model % change in RMSECV
α_opt (min) RMSECV (mM) RMSECV (mM)
1 25 9.5 0.87 1.07 19.10
2 26 11.5 0.52 0.72 27.56
3 26 10.5 0.70 0.97 28.62
4 30 11.1 1.02 1.08 5.74
5 25 8.4 0.68 0.79 13.35
6 26 8.4 0.64 0.82 22.00
7 25 7.5 0.42 0.51 17.61
8 29 8.1 0.76 0.87 12.44
9 31 8.3 0.96 1.00 3.41
10 27 12 0.50 0.53 5.25