Skip to main content
. 2010 Jun 16;48(8):2770–2778. doi: 10.1128/JCM.00654-10

TABLE 3.

Diagnostic accuracy parameters for the IDEIA Norovirus kit

Sample source (n) Diagnostic accuracy (95% CI)
% Overall agreement
Sensitivity Specificity PPV NPV
All samples (557) 57.6 (55.0-59.6) 91.9 (87.9-94.8) 91.5 (87.2-94.6) 59.0 (56.4-60.9) 71.3
Outbreaksa,b (102) 58.7 (52.6-61.6) 88.9 (72.2-97.0) 93.6 (84.0-98.3) 43.6 (35.4-47.6) 66.7
Sporadic cases (136) 59.0 (50.6-64.0) 93.3 (86.5-97.4) 87.8 (75.3-95.2) 73.7 (68.3-76.9) 77.9
Outbreaksb with indicated no. of samples collected
    3 (46) 44.1 (34.3-46.9) 100.0 (71.8-100) 93.8 (72.9-99.7) 38.7 (27.9-41.8) 57.4
    4 (27) 63.2 (47.9-68.1) 100.0 (62.8-100.0) 92.3 (70.0-99.6) 53.3 (34.0-59.6) 71.4
    5 (17) 76.9c (64.6-89.0) 100 (45.4-100.0) 83.3 (70.0-96.4) 40.0 (7.9-71.3) 76.4
    >5 (12) 77.8c (55.8-88.3) 100.0 (38.3-100.0) 100.0 (59.6-97.9) 60.0 (20.5-78.9) 83.3
a

Outbreaks include three or more samples.

b

An outbreak was considered positive if two or more samples were positive.

c

Significantly different from outbreaks in which only three samples were collected (P < 0.05).