Skip to main content
. Author manuscript; available in PMC: 2010 Aug 6.
Published in final edited form as: Lab Chip. 2009 Aug 20;9(21):3131–3143. doi: 10.1039/b904354c

Figure 1.

Figure 1

Single pneumatic valve. (a) A thin diaphragm membrane embedded on the bottom layer opens the upper channel discontinuity in the presence of vacuum in the bottom chamber. (b) Explicit visualization of valve status by the amount of light reflection. The open valve exhibits stronger reflection due to the collapsed membrane.