Skip to main content
. Author manuscript; available in PMC: 2010 Aug 11.
Published in final edited form as: Laryngoscope. 2010 Apr;120(4):764–768. doi: 10.1002/lary.20816

Table 1.

Results of least-squares regressions for the parametric description of elastic shear modulus (G′) and dynamic viscosity (η′) of the injectable biomaterials (n = 3) and the human vocal fold cover (n = 7)6 according to Equations (1) and (2). R 2 is the coefficient of determination indicating the goodness of curve fitting.

G′ = a f b a (Pa.s) b R2
Juvéderm (n = 3) 721.730 0.219 0.795
Cymetra (n = 3) 827.232 0.407 0.826
Atelocollagen (n = 3) 854.108 0.188 0.775
Radiesse (n = 3) 1446.554 0.347 0.768
Normal vocal fold cover (n = 7) 13.388 0.698 0.843
η′ = a f b a (Pa.s 2) b R 2
Juvéderm (n = 3) 74.537 −0.841 0.883
Cymetra (n = 3) 82.045 −0.712 0.944
Atelocollagen (n = 3) 82.300 −0.952 0.989
Radiesse (n = 3) 151.371 −0.793 0.947
Normal vocal fold cover (n = 7) 8.681 −0.709 0.927