Studies examining the emission of radiation for pedicle screw insertion

Study Study design Materials and methods Results/conclusion
Rampersaud et al. [19] In vitro study on cadavers, dorsal spondylodesis Badge measurement and TLD Highest dose ipsilateral on the side of the beamer (53.3 mREM), spine surgeons receive greater radiation than others
Jones et al. [10] 140 patients with fusion of lumbar spine Digital dosimeter for skin (patient) and scatter (surgeon) radiation Duration of radiation: 1.4 minutes per case; recommendation for source-superior position of C-arm
Perisinakis et al. [18] 20 cases with dorsal spondylodesis analyzed regarding duration of radiation and position of fluoroscope RANDO-Phantom with TLD Effective doses: AP beam: 3.31 mS Lateral beam: 1.22 mS