Skip to main content
. Author manuscript; available in PMC: 2010 Aug 12.
Published in final edited form as: J Thromb Haemost. 2008 Jul 24;6(10):1655–1662. doi: 10.1111/j.1538-7836.2008.03095.x

Table 2.

Accuracy of INR4 dose refinement algorithms in the validation cohorts.

R2 MAE (mg/day)
[25%,75%]
Predictions within 1
mg of therapeutic dose
Clinical Algorithm
(N=146)
48% 0.74 [0.29,1.4] 70%
Pharmacogenetic
Algorithm (N=146)
70% 0.73 [0.31,1.29] 73%

MAE=Median Absolute Error. INR4 = International Normalized Ratio after the fourth warfarin dose.