Skip to main content
. Author manuscript; available in PMC: 2010 Aug 13.
Published in final edited form as: J Sep Sci. 2008 Feb;31(2):341–352. doi: 10.1002/jssc.200700307

Table 2.

Conditions for electric field simulations

Equation, domain (Fig. 2) Rotor conductivity (S/m) Voltage profile on electrode array (V) Stator electrode
Simulation 1 1, A 0.05 Φ1 (h) = 5000 (1 − 1((hh1)/le)2) Off
Simulation 2 1, A 0.05/10 Φ1 (h) = 5000 (1 − 1((hh1)/le)2) Off
Simulation 3 1, A 0.05/100 Φ1 (h) = 5000 (1 − 1((hh1)/le)2) Off
Simulation 4 1, A 0.05/1000 Φ1 (h) = 5000 (1 − 1((hh1)/le)2) Off
Simulation 5 1, A 0.05/100 Φ1 (h) = 5000 (1 − 1((hh1)/le)2) Ground
Simulation 6 1, A 0.05/100 Φ2 (h) = 5000 (1 −0.79((hh1)/le)2) Ground
Simulation 7 1, A 0.05/100 Φ3 (h) = −3092 h2 − 17340 h + 5331 Ground