Table 1.
Energy absorption input parameters (early and late α) for the room simulation model and resulting room acoustic parameters (T60 and C50) estimated from model BRIR outputs for each simulated room (R1–R3).
Room | Center frequency (Hz) | R1 | R2 | R3 |
---|---|---|---|---|
Early alpha | Broadband | 0.390 | 0.290 | 0.041 |
Late alpha | 125 | 0.533 | 0.400 | 0.057 |
250 | 0.400 | 0.300 | 0.043 | |
500 | 0.400 | 0.300 | 0.043 | |
1000 | 0.400 | 0.300 | 0.043 | |
2000 | 0.293 | 0.220 | 0.031 | |
4000 | 0.267 | 0.200 | 0.029 | |
T60 (s) | Broadband | 0.316 | 0.420 | 2.966 |
125 | 0.364 | 0.447 | 2.655 | |
250 | 0.293 | 0.412 | 2.750 | |
500 | 0.328 | 0.429 | 2.748 | |
1000 | 0.368 | 0.487 | 3.015 | |
2000 | 0.317 | 0.444 | 3.430 | |
4000 | 0.096 | 0.135 | 1.581 | |
C50 (dB) | Broadband | 25.8 | 13.4 | −6.6 |
125 | 8.5 | −6.0 | −23.5 | |
250 | 11.1 | 0.5 | −17.8 | |
500 | 11.1 | −0.4 | −19.1 | |
1000 | 8.9 | −2.8 | −21.5 | |
2000 | 27.5 | 14.5 | −3.8 | |
4000 | 42.3 | 29.5 | 20.5 |