Table 2.

Intra-observer analyses for the coronary artery flow velocity indices.

Scan 1 Scan 1 Paired t-test 95% CI p-value Correlation COV(%)
mean ± sd mean ± sd Mean difference ICC p-value
PSV (cm/s) 22.1 ± 8.4 22.5 ± 8.3 −0.4 −1.3 to 0.4 0.27 0.99* (p < 0.01) 4
TSV (ms) 65 ± 15 65 ± 15 −0.9 −1.8 to 0.1 0.07 0.99* (p < 0.01) 0
PDV (cm/s) 19.8 ± 6.8 20.2 ± 7.1 −0.5 −1.9 to 0.9 0.48 0.97* (p < 0.01) 11
TDV (ms) 387 ± 51 391 ± 54 −0.4 −10.8 to 2.0 0.16 0.99* (p < 0.01) 3
meanVmax (cm/s) 11.3 ± 3.5 11.8 ± 3.4 −0.5 −0.8 to−0.1 0.01* 0.99* (p < 0.01) 4
PSV/meanVmax 2.0 ± 0.6 1.9 ± 1.5 0.1 −0.0 to 0.1 0.12 0.99* (p < 0.01) 5
PDV/meanVmax 1.8 ± 0.4 1.7 ± 0.5 0.0 −0.1 to 0.1 0.56 0.94* (p < 0.01) 8
PSV/PDV 1.2 ± 0.4 1.2 ± 0.4 0.0 −0.1 to 0.1 0.97 0.97* (p < 0.01) 9
Flow volume (ml/cycle) 11.4 ± 5.4 12.3 ± 6.4 −0.9 −1.8 to 0.1 0.07 0.97* (p < 0.01) 11

PSV: peak systolic velocity in cm/s; TSV: time of PSV in ms; PDV: peak diastolic velocity in cm/s; TDV: time of PDV in ms; meanVmax: maximal velocity averaged over the cardiac cycle; PSV/meanVmax: measure for discriminating the systolic peak in the velocity-time graph; PDV/meanVmax: measure for discriminating the diastolic peak in the velocity-time graph; PSV/PDV: ratio between systolic and diastolic peak velocity; Flow volume: the total amount of coronary flow volume (ml/cycle).

*

Mean and standard deviations (SD) are given for the flow velocity indices. Repeated analyses were compared using the paired t-test, mean difference, 95% confidence intervals (95% CIs) and p-values were given. Agreement between intra-observer analyses was evaluated using intraclass correlation coefficients (ICCs) for absolute agreement.

*

p<0.05. Furthermore coefficients of variance (COVs) were given.