Skip to main content
. Author manuscript; available in PMC: 2011 Feb 15.
Published in final edited form as: Cancer Res. 2010 Jul 27;70(16):6629–6638. doi: 10.1158/0008-5472.CAN-10-1616

Table 1. Intestine lengths, crypt diameters and organ weights of wt and Dvl2 mutant mice.

Measurements of small intestines (n >10 per genotype) and organ weights (n = 3 per genotype) from 120 day-old mice. Crypt diameters (n = 132, 3 mice per genotype) were calculated with AxioVision software (Zeiss); ± represents standard error.

Dvl2 (+/+) Dvl2 (+/−) Dvl2 (−/−) Dvl2(−/−)/Dvl2 (+/+)
(percent)
P value
(t test)
Small intestine (cm) 34.1 ± 0.70 34.9 ± 0.55 25.5 ± 0.26 75 P < 0.005
Crypt width (μm) 41.63 ± 0.42 - 38.63 ± 0.53 93 P < 0.005
Spleen (g) 0.09 ± 0.00 - 0.09 ± 0.01 100 -
Kidneys (g) 0.26 ± 0.01 - 0.29 ± 0.03 111 -
Liver (g) 1.11 ± 0.12 - 1.10 ± 0.27 99 -
Heart (g) 0.12 ± 0.00 - 0.12 ± 0.00 100 -