Skip to main content
. Author manuscript; available in PMC: 2011 Sep 1.
Published in final edited form as: Hear Res. 2010 Jun 2;268(1-2):172–183. doi: 10.1016/j.heares.2010.05.019

Table III.

Quality assessment of molecular models of OC90

OC90 domain Identity % Z score Overall G-factor
OC90D1 35.77 -6.20 0.00
OC90D2 34.00 -5.27 0.16

Homology of the sPLA2-like domain 1 and 2 with their template are reflected by percent sequence identity. The combined conformational energy of all Cβ-Cβ interactions is reflected by the Z score calculated by PROSA II. Low Z scores indicate favorable conformation. The stereochemical quality of the model is reflected by the Overall G-factor, calculated by Procheck. All G-factors are within the range of theoretical tolerance. High G- factors indicate favorable overall stereochemical geometry.