Skip to main content
. 2010 Aug 20;5:25. doi: 10.1186/1745-6673-5-25

Table 3.

FA Ceiling values (ppm) according to places of work, tasks and exposed workers

Places of work Tasks Ceiling Values (ppm) Exposed Workers
Factory Resins production Sample collect (Reactors) 1.09 Reactor operators

Factory Impregnation Machine operation 1.04 Impregnation machine operators

Factory Quality Laboratory Quality control 0.52 Quality Technicians

Pathology and anatomy laboratories Macroscopic examination 5.02 Pathologist

Pathology and anatomy laboratories Disposal of specimen and used solutions 0.95 Technicians and Assistants

Pathology and anatomy laboratories Jar filling 2.51 Assistants

Pathology and anatomy laboratories Specimen wash 2.28 Technicians

Pathology and anatomy laboratories Biopsy 1.91 Technicians