Skip to main content
. Author manuscript; available in PMC: 2011 Sep 8.
Published in final edited form as: Structure. 2010 Sep 8;18(9):1094–1103. doi: 10.1016/j.str.2010.05.015

Table 1.

List of experimental restraints used in ENSEMBLE calculations and agreement between experimental and predicted values. See also Figures S1–S7.

Restraint type I-29–164 Spinophilin417–494 DARPP-321–118 I-2:PP1 complex
# RMSD # RMSD # RMSD # RMSD
13Cα chemical shifts 151 0.35 ppm 77 0.35 ppm 112 0.34 ppm 100 0.33 ppm
13Cβ chemical shifts 143 0.38 ppm 74 0.39 ppm 107 0.39 ppm 94 0.33 ppm
13C′ chemical shifts 151 0.41 ppm 76 0.41 ppm 105 0.42 ppm 100 0.40 ppm
13Hα chemical shifts 151 0.08 ppm 75 0.08 ppm 112 0.08 ppm 100 0.08 ppm
13HN chemical shifts 139 0.17 ppm 67 0.17 ppm 99 0.16 ppm 93 0.17 ppm
PREs 631 0.99 Å 42 0.86 Å 437 0.70 Å 514 20.5 Åb
Rh 1 1.9 Å 1 1.9 Å 1 1.8 Å 0 -
15N R2a 141 0.85 67 0.62 102 0.68 92 0.68
a

The 15N R2 restraints are applied by enforcing a correlation between experimental values and contacts within the ensemble and thus these values represent a Pearson correlation, not an RMSD.

b

The PRE restraints were utilized in a very different way in the I2:PP1 complex than for the unbound intrinsically disordered ensembles which accounts for this large RMSD value – see the Methods for more details.