Skip to main content
. Author manuscript; available in PMC: 2010 Sep 15.
Published in final edited form as: J Appl Polym Sci Symp. 2009 Nov 15;114(4):1992–2002. doi: 10.1002/app.30639

TABLE I.

Effective Diffusivity and FA of Water as Measured by DTI in 1% Hydrogel Samples Embedded with Glass Fibers

Diffusivity in the entire sample
Diffusivity in an ROI
Glass
fiber (%)
λz (cm2/s)
λx (cm2/s)
λy (cm2/s)
FA
λza λz (cm2/s)
λx (cm2/s)
λy (cm2/s)
FA
λza
Mean
(×10−7)
SD
(×10−9)
Mean
(×10−7)
SD
(×10−9)
Mean
(×10−7)
SD
(×10−9)
Mean SD
(×10−3)
Mean
(×10−7)
SD
(×10−9)
Mean
(×10−7)
SD
(×10−9)
Mean
(×10−7)
SD
(×10−9)
Mean SD
(×10−3)
0 2.13 2.64 1.98 3.23 1.88 0.35 0.064 6.45 1.10 2.13 0.76 1.97 0.98 1.88 0.84 0.065 1.69 1.10
5 2.17 0.75 1.93 0.45 1.80 0.69 0.098 2.69 1.16 2.19 0.84 1.77 1.45 1.64 1.31 0.16 4.94 1.28
10 2.16 0.75 1.85 0.83 1.73 1.01 0.12 2.34 1.20 2.16 1.15 1.65 1.63 1.52 1.53 0.2 6.50 1.36
20 2.29 2.62 1.89 1.87 1.75 2.04 0.15 1.96 1.26 2.31 1.14 1.71 1.07 1.58 1.21 0.21 3.82 1.40

Measures were over the entire sample and a local ROI (see Fig. 3).

a

λ was calculated as the average of λx and λy.