Skip to main content
. 2010 Sep 27;54(7):762–773. doi: 10.1093/annhyg/meq023

Table 1.

Descriptive statistics of underground area air measurements for DE components in seven non-metal mining facilities

DE component n % <LOD AM GM GSD GSDbf GSDwf 10th percentile 90th percentile
EC measurements (μg m−3)
    TEC 177 9 171 66 5.2 2.7 3.8 5 450
    REC 176 7 159 66 4.7 2.6 3.4 8 443
    SEC 163 16 115 44 5.2 2.8 3.9 3 281
OC measurements (μg m−3)
    TOC 177 2 150 125 1.9 1.2 1.9 57 274
    ROC 177 2 92 78 1.8 1.3 1.8 38 165
    SOC 166 1 109 90 2.0 1.5 1.8 37 187
Gaseous measurements (ppm)
    NO 179 10 1.48 0.67 4.8 2.2 4.0 0.04 3.57
    NO2 179 41 0.50 0.11 7.5 5.1 3.8 0.01 1.32
    CO 171 15 2.87 1.52 3.7 2.0 3.2 0.20 6.23
    CO2 164 0 794 736 1.5 1.4 1.3 502 1274
Particulate measurements (mg m−3)
    TD 178 1 3.37 1.41 3.9 1.4 3.7 0.29 6.58
    RD 172 2 0.89 0.47 3.2 1.8 2.8 0.12 2.12
    SMDa 93 5 0.32 0.18 4.6 2.0 4.2 0.06 0.60
    SCD 164 27 0.17 0.04 7.7 2.0 6.9 0.002 0.35

n = number of measurements; % <LOD = percentage of measurements below the LOD; AM = arithmetic mean; GM = geometric mean; GSDbf = geometric standard deviation of the between-facility distribution of air concentrations; GSDwf = geometric standard deviation of the within-facility distribution of air concentrations; 10th percentile = 10th percentile of the exposure distribution; 90th percentile = 90th percentile of the exposure distribution.

a

For three facilities the SMD filters were not re-weighed before the SCD analysis and therefore SMD is missing for Facilities D, G, and I.