Threshold currents in μA for the same electrode positions as in Fig. 3B

zel=in μm 14 25 35 50 71 100 141 200 Pulse
Dendrite xel=−300 μm ×
×
×
×
×
×
×
44
×
56
50
62
80
75
90
135
130
150
260
230
210
520
460
310

−/+
+/−
Soma xel=0 8,1 17 24 36 59 97 171 330
6,4 15 23 38 62 110 200 400 −/+
8,9 21 34 57 100 190 390 760 +/−
Distal AIS xel=70 μm 3,2
3,3
3,6
6,3
6,6
7,5
10
10,4
12,4
17
18
23
30
31
43
55
60
86
106
120
190
220
250
450

−/+
+/−