Table 1.
Threshold currents in μA for the same electrode positions as in Fig. 3B
zel=in μm | 14 | 25 | 35 | 50 | 71 | 100 | 141 | 200 | Pulse |
---|---|---|---|---|---|---|---|---|---|
Dendrite xel=−300 μm | × × × |
× × × |
× 44 × |
56 50 62 |
80 75 90 |
135 130 150 |
260 230 210 |
520 460 310 |
– −/+ +/− |
Soma xel=0 | 8,1 | 17 | 24 | 36 | 59 | 97 | 171 | 330 | – |
6,4 | 15 | 23 | 38 | 62 | 110 | 200 | 400 | −/+ | |
8,9 | 21 | 34 | 57 | 100 | 190 | 390 | 760 | +/− | |
Distal AIS xel=70 μm | 3,2 3,3 3,6 |
6,3 6,6 7,5 |
10 10,4 12,4 |
17 18 23 |
30 31 43 |
55 60 86 |
106 120 190 |
220 250 450 |
– −/+ +/− |
Stimulation with monophasic cathodic and charge balanced triphasic (cathodic first and anodic first) pulses, 100 μs per phase. The triphasic pulses have a gap of 100 μs after the first pulse and show a threshold characteristic quite similar to biphasic 200 μs pulses of the same charge per phase.