Table 2.

Median (± SEM) Percent True-Positive Detection Rates for the Identification of Insulin Secretory Bursts Using the Two Analytical Methods AutoDecon and Cluster

Sampling duration (min): 30 60 120
Analytical method: AutoDecon Cluster AutoDecon Cluster AutoDecon Cluster
Sampling frequency Replicates
Every 30 seconds Singlicates 91.9 ± 0.45 79.4 ± 0.71 93.4 ± 0.33 80.6 ± 0.47 96.2 ± 0.18 80.1 ± 0.32
Duplicates 91.9 ± 0.48 84.9 ± 0.61 93.6 ± 0.33 83.9 ± 0.43 95.8 ± 0.20 89.0 ± 0.33
Triplicates 91.4 ± 0.48 78.3 ± 0.61 93.8 ± 0.36 76.9 ± 0.45 96.5 ± 0.18 74.9 ± 0.31
Every 1 minute Singlicates 95.5 ± 0.46 89.9 ± 0.76 97.2 ± 0.22 93.5 ± 0.38 97.5 ± 0.16 90.8 ± 0.30
Duplicates 96.2 ± 0.33 94.4 ± 0.55 96.6 ± 0.24 83.7 ± 0.42 97.4 ± 0.15 93.8 ± 0.25
Triplicates 95.3 ± 0.40 93.5 ± 0.46 95.6 ± 0.26 94.0 ± 0.30 97.0 ± 0.16 92.9 ± 0.24
Every 2 minutes Singlicates 80.7 ± 1.30 89.5 ± 0.95 97.2 ± 0.48 97.4 ± 0.30 99.4 ± 0.18 96.6 ± 0.26
Duplicates 80.0 ± 1.30 92.7 ± 0.80 98.7 ± 0.29 98.7 ± 0.24 99.5 ± 0.07 98.0 ± 0.17
Triplicates 84.4 ± 1.10 96.9 ± 0.51 98.5 ± 0.30 99.0 ± 0.20 99.4 ± 0.01 98.6 ± 0.13