Skip to main content
. 2010 Oct 15;4:128. doi: 10.3389/fncel.2010.00128

Table 1.

Estimation of ET (SR) and P1 for single fEPSPs under various conditions.

2 mM [Ca2+]o 4 mM [Ca2+]o
Pressure P1 ET P1 ET
0.1 MPa 0.35 ± 0.11 1.03 ± 0.37 0.44 ± 0.1§ 1 ± 0.23 (ET’)
10.1 MPa 0.27 ± 0.04 0.64 ± 0.09** 0.39 ± 0.07§ 0.53 ± 0.1*,**

P1 at HP was calculated using the ET for their respective conditions. Mean ± SE, n = 6. §p < 0.01 with respect of its respective control pressure; *p < 0.02, ET is significantly smaller (17%) at constant HP and increased [Ca2+]o, n = 6; **p < 0.01, HP significantly reduces ET with respect to control pressure.