Table 1.

WHO medical eligibility criteria contraindications to levonorgestrel-releasing intrauterine system insertion

(Category 4 or risk is unacceptable)
  • Current pregnancy

  • Current purulent cervicitis or pelvic infection (delay insertion until treatment is complete)

  • Immediate post-septic abortion

  • Current malignant gestational trophoblastic disease

  • Current breast cancer

  • Untreated cervical cancer

  • Untreated endometrial cancer

  • Unexplained vaginal bleeding

  • Distorted uterine cavity (any congenital or acquired abnormality interfering with IUD insertion, including uterine fibroids)

  • Known pelvic tuberculosis

Data from World Health Organization 2004.5