Table 2.

Comparison between the given principal direction and outcomes from RT and LF algorithms

True Rotation Degree θ0(°) LF result θ1 (°) LF Accuracy (%) RT result θ2 (°) RT Accuracy (%)
30 30.11 0.4 30 0.0
60 59.9 −0.2 60 0.0
90 94.2 4.7 92 2.2
120 120.51 0.4 120 0.0
150 150.31 0.2 150 0.0
180 180.17 0.1 180 0.0

Column one is the rotated degrees of Figure 4 from the prescribed principal direction. Columns two and four are, respectively, the principal directions computed by the LF and RT algorithms. The accuracies (θ1θ0)/θ0 are listed in columns three and five as percents.