Skip to main content
. 2010 Oct;65(10):1003–1007. doi: 10.1590/S1807-59322010001000013

Table 4.

Comparison of pulmonary functional tests (PFT) between control group and carpenters.

PFT Values Control group Carpenters 95% CI Stat. dif. Power
FVC 94.19±13.83 58.34±17.87 30.00 ‐ 41.69 p< 0.001 1.00
FEV1 95.88±13.72 61.72±17.88 28.33 ‐ 39.99 p< 0.001 1.00
FEV1/FVC 102.50±11.78 107.06±24.83 ‐35.88 ‐ ‐23.43 NS 0.26
MMEF 96.14±20.46 69.59±32.51 16.54 ‐ 36.57 p< 0.001 0.99
PEF 95.36±19.86 45.39±23.42 42.06 ‐ 57.88 p< 0.001 1.00
MEF75% 101.40±21.62 45.36±26.81 47.15 ‐ 64.93 p< 0.001 1.00
MEF50% 100.49±27.23 68.09±32.34 21.51 ‐ 43.30 p< 0.001 0.99
MEF25% 102.34±27.42 118.86±54.42 ‐32.52 ‐ ‐0.519 p< 0.05 0.58

Values are presented as mean ± SD of percent predicted (for each group; n = 66). FVC: forced vital capacity; FEV1: forced expiratory volume in one second; MMEF: maximal mid‐expiratory flow; PEF: peak expiratory flow; MEF75, MEF50, and MEF25: maximal expiratory flow at 75%, 50%, and 25% of the FVC, respectively; Stat. dif.: statistical differences.