Table 4.
Comparison of pulmonary functional tests (PFT) between control group and carpenters.
PFT Values | Control group | Carpenters | 95% CI | Stat. dif. | Power |
FVC | 94.19±13.83 | 58.34±17.87 | 30.00 ‐ 41.69 | p< 0.001 | 1.00 |
FEV1 | 95.88±13.72 | 61.72±17.88 | 28.33 ‐ 39.99 | p< 0.001 | 1.00 |
FEV1/FVC | 102.50±11.78 | 107.06±24.83 | ‐35.88 ‐ ‐23.43 | NS | 0.26 |
MMEF | 96.14±20.46 | 69.59±32.51 | 16.54 ‐ 36.57 | p< 0.001 | 0.99 |
PEF | 95.36±19.86 | 45.39±23.42 | 42.06 ‐ 57.88 | p< 0.001 | 1.00 |
MEF75% | 101.40±21.62 | 45.36±26.81 | 47.15 ‐ 64.93 | p< 0.001 | 1.00 |
MEF50% | 100.49±27.23 | 68.09±32.34 | 21.51 ‐ 43.30 | p< 0.001 | 0.99 |
MEF25% | 102.34±27.42 | 118.86±54.42 | ‐32.52 ‐ ‐0.519 | p< 0.05 | 0.58 |
Values are presented as mean ± SD of percent predicted (for each group; n = 66). FVC: forced vital capacity; FEV1: forced expiratory volume in one second; MMEF: maximal mid‐expiratory flow; PEF: peak expiratory flow; MEF75, MEF50, and MEF25: maximal expiratory flow at 75%, 50%, and 25% of the FVC, respectively; Stat. dif.: statistical differences.