Skip to main content
. 2008 Apr 2;9(2):521–527. doi: 10.1208/s12249-008-9072-6

Fig. 2.

Fig. 2

Influence of temperature on mucociliary particle transport rates. Decreased (20 °C) as well as increased (45 °C) temperature resulted in significant reduction of particle transport rates. Numbers beside the bars e.g. “100/6” represent 100 particles tracked on six tracheas