Skip to main content
. 2010 Apr 13;19(8):1288–1298. doi: 10.1007/s00586-010-1380-3

Table 3.

Assessment of atlantoaxial load–displacement (mm) under incremental failure-load testing (10 N to failure) with electromechanic testing machine, TAL disrupted

Loading 10 N 20 N 30 N 40 N 50 N 100 N 150 N 200 Na 250 Na 300 Nb
Mean 0.01 0.37 0.67 0.90 1.10 1.92 2.79 3.52 4.63 5.97
SD 0.01 0.25 0.33 0.42 0.48 0.70 0.95 1.38 1.94 1.33
Range 0.01–0.02 0.01–0.72 0.17–1.10 0.27–1.41 0.34–1.60 0.73–2.40 1.12–3.44 1.54–4.61 2.05–6.39 5.03–6.91

aData of four specimens succeeding loading condition