Skip to main content
. 2009 May 19;28(15):1982–1998. doi: 10.1002/sim.3618

Table III.

Simulation results for parameter β in univariate model with binary X.

Settings Analyses


Model β n PERFECT CC NO-T LOGT T T2 NA COX COX*
Bias
Base case* 0 336 0.00 −0.01 −0.01 −0.01 −0.01 −0.01 −0.01 −0.01 −0.01
0.5 336 0.00 0.00 −0.26 −0.06 0.00 −0.02 0.00 0.00 0.00
1 84 0.01 0.03 −0.52 −0.08 0.03 0.02 0.03 0.04 0.04
Shape 2 1 84 0.01 0.03 −0.52 −0.08 0.00 0.03 0.03 0.04 0.04
Admin cens 1 84 0.01 0.03 −0.51 0.01 0.02 0.02 0.02 0.02 0.02
Per cent error in model standard error
Base case 0 336 0 1 71 4 −1 0 −1 0 1
0.5 336 −1 1 73 5 0 −1 0 0 0
1 84 −2 −6 74 4 −2 −4 −2 −4 −2
Shape 2 1 84 −2 −6 74 4 0 −2 −2 −4 −2
Admin cens 1 84 −4 −1 74 −1 −2 −2 −2 0 0
Power
Base case 0.5 336 92 65 14 59 65 62 65 64 64
1 84 92 64 12 57 64 60 63 64 65
Shape 2 1 84 92 64 12 57 63 64 63 64 64
Admin cens 1 84 96 73 17 71 73 73 72 71 71
*

Base case: πM = 0.5, πX = 0.5, λT =0.002, shape κ=1, random censoring with λC = 0.002.

Administrative censoring.

Monte Carlo error: ≤0.016 for bias, ≤4 per cent for per cent error in model standard error, ≤1.6 per cent for power. Bold cells have bias greater than 0.03, more than 10 per cent error in model standard error or power more than 3 per cent worse than method T.