Skip to main content
. 2010 Oct 4;38(22):e202. doi: 10.1093/nar/gkq836

Table 1.

Laser parameters used in previous chromosome studies

Laser type Nd:YAG Excimer pumped dye laser PALM microlaser system Nd:YVO4 Nd: YAG Fs Ti: sapphire NIR
Wavelength (nm) 266 340 337 355 532 1064 800 800 780
Pulse width 5.7 ns 17 ns 4 ns 2 ns 12 ns 12 ps 100 ps 170 fs 200 fs 200 fs
Repetition rate 10 Hz 10 Hz 60 Hz 100 Hz 20 KHz 76 MHz 70 MHz 80 MHz 76 MHz 76 MHz
Objective Mag./N.A. ×100/1.25 NA ×100/0.85 NA ×100/1.2 NA ×100/1.3 NA ×63/1.4 NA ×63/1.4 NA ×63/1.4 NA ×100/1.3 NA ×63/1.4 NA ×63/1.4 NA
Spot diameter (µm) 0.26 0.49 0.32 0.33 0.46 0.46 0.93 0.75 0.70 0.68
Energy/pulse 9 nJ NA 0.7 uJ 6.75 uJ 377 nJ 0.098 nJ 0.0071 nJ 0.19 nJ 0.13 nJ 0.28 nJ, 0.41 nJ
Number of pulses 1 NA ∼360 NA 200 2.28 × 107 2.1–4.2 × 109 1.04–800 × 105 6.54 × 106 7.6 × 105
Total energy delivered 9 nJ NA ∼252 uJ NA 75.4 uJ 2234.4 µJ 15–30 J 19.5–15 000 uJ 850 uJ 210 uJ, 310 uJ
Peak irradiance (W/cm2) 2.98 × 109 NA 6.36 × 1011 NA 1.86 × 1010 4.84 × 109 1.02–1.27 × 107 2.49 × 1011 1.72 × 1011 3.81 × 1011, 5.62 × 1011
Reference 43 44 45 46 This study Personal communication 47 48 13 This study

References (44,45,48) were carried out on extracted chromosomes. NA = not available.