Table 1.

Target and normal tissue planning criteria, for 6 fractions.

Region of interest Dose criteria Limit* Limit if the PTV overlaps non-liver normal tissues
GTV Min to 0.5 cm3 95% of prescription n/a
PTVGTV Min (max) to 0.5 cm3 volume 95% (140%) of prescription 80% of prescription
PTVCTV Min to 0.5 cm3 27.0 Gy n/a
Large Bowel Max to 0.5 cm3 28.2 Gy 30.0 Gy
Small Bowel Max to 0.5 cm3 28.2 – 33.6 Gy 30.0 – 36.0 Gy
Stomach Max to 0.5 cm3 28.2 – 30.0 Gy 30.0 – 33.6 Gy
Duodenum, esophagus Max to 0.5 cm3 28.2 Gy 30.0 Gy
Kidney(s) Mean to one or combined kidneys 10 Gy n/a

Abbreviations: GTV = gross tumor volume; CTV = clinical target volume (GTV plus 0.8 cm expansion in liver); PTV = planning target volume (patient specific internal margin for breathing plus 0.3 cm setup margin expansion); PTVGTV = PTV applied around the GTV; PTVCTV = PTV applied around the CTV.

Notes:

*

Ranges indicate criteria was modified during the course of the trial

For each patient the same PTV expansion was applied to each the GTV and CTV though dose criteria was different.