Skip to main content
. 2010 Dec 2;10:343. doi: 10.1186/1471-2334-10-343

Table 2.

Environmental findings from the workplace of Case B, plant B and mill B

Date
(before or after infection)
Water systems sampled
(sample type)
Temperature (°C) Legionella concentration
(cfu/l)
Type of Legionella
16th Aug 2005
(before)
Active sludge basin
at the waste water treatment plant B (water)
37.7 3.0 × 107 L. pneumophila serogroup 5

15th Nov 2006
(after)
Active sludge basin
at the waste water treatment plant B (water)
35.2 4.3 × 107 and
8.0 × 109
L. pneumophila serogroup 5 and L. rubrilucens

15th Nov 2006
(after)
Cooling tower at the waste water treatment plant B (water) 37.3 1.7 × 103 L. pneumophila serogroup 2

15th Nov 2006
(after)
Well of rejected waste water at plant B (water) 31.0 3.2 × 107 and
2.0 × 108
L. pneumophila serogroup 5 and L. rubrilucens

15th Nov 2006
(after)
Process water, paper machine X, mill B (water) 50.0 Not detected

15th Nov 2006
(after)
Process water, paper machines X and Y, mill B (water) 35.1 Not detected

15th Nov 2006
(after)
Shower water system in mill B, used by Case B (water) 35.0 Not detected