Skip to main content
. Author manuscript; available in PMC: 2011 Jan 6.
Published in final edited form as: Pharm Res. 2010 May 19;28(1):41–57. doi: 10.1007/s11095-010-0169-8

Table VI.

Influence of MN Geometry on Force Required to Induce Transverse Failure of MN Prepared from Aqueous Blends Containing 20% w/w Gantrez® AN 139

Model Force/Needle (N) % Reduction in Height of MN arrays
1 0.08±0.03 37.48±2.90
6 0.17±0.10 50.43±3.39
7 0.09±0.02 33.38±8.01

(Means ± SD, n=36)