Skip to main content
. 2010 Oct 15;469(2):464–469. doi: 10.1007/s11999-010-1624-x

Table 4.

Comparison of sensitivity, specificity, positive predictive value, negative predictive value and accuracy (with confidence intervals) of the three views in comparison to the axial oblique MRI values

View AP Cross table Dunn
Sensitivity 0.60 (0.44–0.75) 0.74 (0.59–0.86) 0.91 (0.78–0.97)
Specificity 0.81 (0.58–0.95) 0.63 (0.38–0.84) 0.88 (0.68–0.97)
PPV 0.60 (0.69–0.96) 0.82 (0.66–0.92) 0.93 (0.80–0.98)
NPV 0.50 (0.32–0.68) 0.52 (0.31–0.73) 0.84 (0.64–0.95)
Accuracy 0.67 (0.54–0.78) 0.71 (0.58–0.82) 0.90 (0.80–0.96)