Skip to main content
. 2010 Oct 13;469(2):600–606. doi: 10.1007/s11999-010-1626-8

Table 2.

Compression and fracture test results

Test Cellulose cement Traditional cement Plain cement
Compression strength (MPa) 92.1 ± 4.8 (85.1–101.9) 75.3 ± 8.1 (66.2–87.6) 95.2 ± 5.1 (88.4–104.7)
Fracture toughness (MPa√m) 1.75 ± 0.05 (1.66–1.87) 1.48 ± 0.11 (1.31–1.69) 1.81 ± 0.05 (1.72–1.87)

Values are expressed as mean ± SD, with range in parentheses.