Table 3.

Comparison of Before and After Repair Geometric Data for CE-Physio Rings (Full) for Ischemic and Myxomatous Mitral Valves

Nonplanarity Angle (Degrees)
Circularity Index (AP/AL-PM
Diameter)
CE-Physio Rings Before Repair After Repair Before Repair After Repair
All cases, n = 24 (ischemic/nonischemic) 136.16 ± 12.37 149.03 ± 14.88 0.94 ± 0.08 0.84 ± 0.11
p = 0.00a p = 0.001a
Nonischemic, n = 12 136.87 ± 12.81 147.71 ± 15.3 0.93 ± 0.09 0.82 ± 0.09
p = 0.043a p = 0.043a
Ischemic, n = 12 135.45 ± 12.45 150.40 ± 15.00 0.96 ± 0.06 0.87 ± 0.12
p = 0.00a p = 0.030a
a

Statistically significant.

AL = anterolateral; AP = anteroposterior; CE = Carpentier-Edwards; ML = mediolateral; PM = posteromedial.