Figure 3.
Mean stop times of platelets rolling on vWF-A1 molecules: (A) wt vWF-A1 (n = 14–256), (B) GOF R687E vWF-A1 (n = 5–104), and (C) LOF G561S vWF-A1 (n = 11–382). Data represent the mean ± SE. Each catch-slip transition is statistically significant with p < 0.05.