Table 3.
Error Correlations Withina and Betweenb Self-Report Instruments for Total Carotenoid Intake in a WHEL Sample of 3,088 Breast Cancer Survivors Recruited Between 1995 and 2000 and Followed Through 2006
Assessment Methodc and Year | Error Correlation in Repeated Plasma Measures (r) |
|||||||
r = 0 |
r = 0.3d |
|||||||
Comparison (n = 1,551) |
Intervention (n = 1,537) |
Comparison (n = 1,551) |
Intervention (n = 1,537) |
|||||
Error Correlation Estimate | 95% Credible Interval | Error Correlation Estimate | 95% Credible Interval | Error Correlation Estimate | 95% Credible Interval | Error Correlation Estimate | 95% Credible Interval | |
Within 24-hour recalls | ||||||||
Baseline, 1 year | 0.32 | 0.27, 0.37 | 0.02 | −0.06, 0.10 | 0.32 | 0.27, 0.38 | 0.00 | −0.07, 0.08 |
Baseline, 4 years | 0.27 | 0.21, 0.33 | 0.09 | 0.02, 0.16 | 0.27 | 0.21, 0.33 | 0.08 | 0.01, 0.15 |
1 year, 4 years | 0.42 | 0.37, 0.48 | 0.59 | 0.53, 0.63 | 0.43 | 0.37, 0.48 | 0.59 | 0.54, 0.64 |
Within Arizona food frequency questionnaire | ||||||||
Baseline, 1 year | 0.55 | 0.50, 0.59 | 0.19 | 0.12, 0.26 | 0.55 | 0.51, 0.59 | 0.17 | 0.10, 0.24 |
Baseline, 4 years | 0.39 | 0.33, 0.44 | 0.23 | 0.17, 0.30 | 0.39 | 0.34, 0.44 | 0.23 | 0.16, 0.29 |
1 year, 4 years | 0.51 | 0.46, 0.56 | 0.58 | 0.52, 0.63 | 0.51 | 0.46, 0.56 | 0.58 | 0.53, 0.63 |
Between Arizona food frequency questionnaire and 24-hour recalls | ||||||||
Baseline | 0.40 | 0.36, 0.45 | 0.40 | 0.36, 0.45 | 0.41 | 0.36, 0.45 | 0.41 | 0.36, 0.45 |
1 year | 0.42 | 0.36, 0.47 | 0.68 | 0.65, 0.72 | 0.42 | 0.36, 0.47 | 0.69 | 0.65, 0.72 |
4 years | 0.39 | 0.34, 0.44 | 0.51 | 0.45, 0.56 | 0.39 | 0.34, 0.44 | 0.51 | 0.46, 0.56 |
Abbreviation: WHEL, Women's Healthy Eating and Living.
Within-instrument error correlations represent systematic error and can be interpreted as the proportion of error variance due to subject-specific bias.
Between-instrument error correlations represent shared systematic error (e.g., recall bias) between instruments.
Self-reported dietary intakes adjusted for body mass index and total caloric intake; plasma markers adjusted for plasma cholesterol and body mass index.
Assumed first-order autoregressive correlation structure for plasma error matrix.