Table 4.

Variations in the lateral depth to the distal tumor volume surface (D2DT), and the position of the prescription iso-dose (combined dose from 2 lateral beams). For both left and right sides, the positive shift is defined as the expansion of the iso-dose towards the respective lateral surface.

Case Plan CT D2DT [mm]
In-room CT
D2DT mean ± standard deviation [mm] Shift in the position of prescription iso-dose [mm]
Left Right * Left Right * Left Right
1 218 220 221 ± 2 221 ± 3 0.9 ± 2.3 −0.5 ± 2.1
2 282 277 280 ± 3 281 ± 4 3.1 ± 2.8 −0.4 ± 2.5
3 237 226 235 ± 2 228 ± 3 −1.2 ± 1.6 −1.2 ± 1.6
4 243 241 249 ± 3 244 ± 3 −1.6 ± 1.6 −0.7 ± 1.6
5 199 202 200 ± 2 204 ± 2 1.7 ± 1.9 −0.7 ± 1.8
6 199 206 204 ± 2 206 ± 2 1.0 ± 1.8 −1.7 ± 1.8
7 190 192 191 ± 2 191 ± 2 −0.5 ± 1.4 −0.5 ± 1.3
8 197 200 200 ± 2 204 ± 1 0.1 ± 1.4 1.0 ± 1.4
9 232 230 237 ± 2 232 ± 2 0.1 ± 1.5 0.8 ± 1.3
10 208 207 206 ± 2 204 ± 2 0.1 ± 2.1 −2.2 ± 2.2
*

Repeated from Table 3 for convenience

Abbreviations: CT = computed tomography scan, D2DT = depth to distal tumor volume surface