Skip to main content
. 2010 Dec 10;77(3):1148–1150. doi: 10.1128/AEM.01829-10

TABLE 1.

Water quality comparison using saltwater AOC and TOCa

Source and type of water AOC (μg acetate-carbon/liter) (mean ± SD) TOC (mg/liter) (mean ± SD)
Tampa Bay, FL
    Tampa Bay raw 360 ± 180 5.4 ± 0.3
    Chlorine dioxide 440 ± 290 5.4 ± 0.3
    Pre-sand filtration 150 ± 90 5.1 ± 0.2
    Post-sand filtration 30 ± 10 4.9 ± 0.2
    Diatomaceous earth filters 30 ± 10 4.9 ± 0.1
    Cartridge filters 130 ± 90 4.9 ± 0.1
Monterey Bay, CA
    Raw inlet 30 ± 20 1.4 ± 0.4
    Self-cleaning filter (100 μm) 20 ± 20 1.5 ± 0.4
    Ultrafilter
        0.04-μm pore size 10 ± 10 1.5 ± 0.6
        0.01-μm pore size 10 ± 15 1.5 ± 0.7
    Cartridge filters <10 1.4 ± 0.5
a

Testing was performed on samples collected at the Tampa Bay Desalination Facility, Florida, and the Moss Landing, California, desalination pilot plant. Florida samples were collected over three consecutive days in November 2009, and California samples were collected in March, June, September, October, November, and December 2009.