Table 2.

Simulated spatial distribution quantitative analysis for reconstructed sources: APSF and SHIFT for the eLCMA, LCMA, eLCMV, and LCMV beamformers.

Motor area:
APSF (mm) SHIFT (mm)
SNR eLCMA LCMA eLCMV LCMV eLCMA LCMA eLCMV LCMV
1 1.54 1.60 3.44 3.30 0.42 0.58 0.27 0.29
5 1.68 1.01 3.36 3.38 0.50 0.29 0.23 0.22
10 1.63 1.01 3.39 3.32 0.26 0.25 0.25 0.24
30 2.00 1.61 3.66 3.15 0.37 0.38 0.23 0.23
Average 1.71 1.31 3.47 3.29 0.39 0.37 0.25 0.25
Visual area:
APSF (mm) SHIFT (mm)
SNR eLCMA LCMA eLCMV LCMV eLCMA LCMA eLCMV LCMV
1 1.19 1.02 3.31 3.15 0.54 0.26 0.21 0.23
5 1.25 1.57 3.25 3.17 0.66 0.35 0.31 0.23
10 1.55 1.49 3.26 3.15 0.31 0.31 0.30 0.29
30 1.87 1.18 3.29 3.12 0.56 0.48 0.25 0.23
Average 1.46 1.32 3.28 3.14 0.52 0.35 0.27 0.24