Skip to main content
. 2011 Jan 27;12:74. doi: 10.1186/1471-2164-12-74

Table 2.

Tests of accuracy

Class Priors Counts Sensitivityd PPVe

Test set 1a Test set 2b Test set 3c Test set 1 Test set 2 Test set 3 Test set 1 Test set 2 Test set 3
Nucleolar-enriched 0.20 30 15 52 0.72 0.78 0.56 0.68 0.61 0.47

Nucleolar-nucleoplasmic 0.15 22 7 24 0.73 0.57 0.50 0.63 0.60 0.41

Nucleolar-cytoplasmic 0.15 24 16 63 0.77 0.69 0.59 0.70 0.74 0.53

Non-nucleolar 0.50 200 100 344 0.90 0.91 0.81 0.94 0.93 0.87

a Test set 1: leave-one-out cross-validation test

b Test set 2: independent literature-based test

c Test set 3: SILAC experimental independent test

d These sensitivity measures represent average sensitivity values over ten runs. Their standard deviations were all below 0.03.

e PPV: positive predictive value. These measures represent average PPV values over ten runs. Their standard deviations were all below 0.1.