Skip to main content
. Author manuscript; available in PMC: 2012 Mar 1.
Published in final edited form as: Ear Hear. 2011 Mar–Apr;32(2):238–250. doi: 10.1097/AUD.0b013e3181fb8390

Table 4.

Place-pitch discrimination thresholds for individual subjects. A value of “>1” indicates that the subject was not able to discriminate between the two physical electrodes in the pair. These values were excluded from computations of the mean and standard error.

Subj apical middle basal
CI-6L >1 0.15 >1
CI-17 0.16 0.30 0.16
CI-22 0.43 0.21 0.96
CI-23 0.49 0.22 0.44
CI-24 0.30 0.14 0.44
CI-25 >1 0.78 0.96
CI-26 0.85 0.58 >1
CI-27 0.36 0.28 0.80
CI-28 0.23 0.45 0.35
CI-30 0.69 0.32 0.09

mean* 0.44 0.34 0.53
s.e.* 0.08 0.07 0.12
*

excludes values > 1