Table 3.
Sensitivity of the Blink Reflex Test for the Different Outcomes of Brain MRI
| MRI* brain (gold standard) | No. of Positive/ Total Sensitivity of BRT† (95% CI‡ ) | |
|---|---|---|
| Overall | 59/65 90.8% (83.7-97.8%)  | 
|
| Presence of BS§ lesions | none | 27/30 90.0% (79.3-100%)  | 
| ≥ 1 | 32/35 91.4% (82.2-100%)  | 
|
| Gadolinium enhancement, overall | none | 40/43 93% (85.4-100%)  | 
| in ≥ 1 lesions | 19/22 86.4% (72-100%)  | 
|
| Gadolinium enhancement, specifically | in BS§ lesions (and hemispheric) | 5/5 100%  | 
| only in hemispheric lesions | 14/17 82.4% (64.2-100%)  | 
|
MRI: Magnetic Resonance Imaging.
BRT: Blink Reflex Test.
CI: Confidence Interval.
BS: Brainstem.