Skip to main content
. 2007 Mar 6;21(2):208–218. doi: 10.1007/s10278-007-9026-7

Table 2.

Intraexaminer Reliability (ICC), 95% Confidence Interval (CI), Standard Error of Measurement (SEM), Mean, and Standard Deviation (SD) for Each Method and Both Examiners

Method Examiner ICC CI SEM Mean SD
Manual 1 0.95 (0.91, 0.98) 2.09 26.74 9.53
2 0.95 (0.90, 0.98) 2.28 29.02 10.31
Semiautomated 1 0.94 (0.88, 0.97) 2.97 33.45 12.19
2 0.92 (0.85, 0.96) 3.39 34.41 12.33
Automated 1 0.91 (0.84, 0.96) 2.30 24.67 7.86
2 0.96 (0.92, 0.98) 1.71 24.11 8.39