Skip to main content
. 2003 Dec 15;16(3):280–291. doi: 10.1007/s10278-003-1655-x

Table 1.

Results of automatic detection algorithm for identifying the view of chest radiographs

Pixel Size of Feature image
Distance Measure Number of References 64 × 64 32 × 32 16 × 16 8 × 8 4 × 4 2 × 2 1 × 1
DE 1,867 98.66 98.66 98.72 98.66 98.86 94.80 81.41
430 98.77 98.77 98.93 98.82 98.82 94.54 81.90
5 90.52 90.79 90.09 89.56 87.47 992.98 84.52
DV 1,867 99.20 99.20 99.09 99.14 98.39 91.64 67.81
430 98.77 98.72 98.66 98.55 97.00 91.12 67.54
5 96.63 96.52 95.82 95.82 90.31 90.47 67.76
Df 1,867 99.46 99.57 99.25 99.25 98.39
430 98.93 99.04 98.93 98.39 97.00
5 96.89 96.84 96.79 95.45 90.31
Dr 1,867 99.62 99.68 99.46 98.55 94.06
430 99.25 99.25 99.20 97.97 94.86
5 95.02 96.14 96.47 87.63 87.63