Skip to main content
. Author manuscript; available in PMC: 2011 Jul 6.
Published in final edited form as: Diab Vasc Dis Res. 2010 Jul 6;7(3):216–224. doi: 10.1177/1479164110375297

Table 3.

Multivariate logistic regression model for renal measures in the Pittsburgh EDC Pulse Wave Analysis study population

Model 1a Model 2b Model 3b
Microalbuminuriac GFR < 60 ml/min/1.73 m2 Cystatin C ≥ 1.0 mg/l
Variable OR 95% CI p-value OR 95% CI p-value OR 95% CI p-value
SEVR 0.35 0.17–0.73 .005 0.44 0.22–0.89 .02 0.31 0.13–0.73 .007
eGDR 0.52 0.30–0.89 .017 --- --- --- --- --- ---
Heart Rate 0.72 0.38–1.38 .32 0.42 0.20–0.88 .02 0.20 0.07–0.57 .003
ACEI/ARB Use --- --- --- 3.57 1.18–10.8 .02 5.65 1.21–26.4 .03
Hypertension --- --- --- --- --- --- 6.35 1.88–21.5 .003

Odds Ratios are per standardized unit.

a

Variables available to Model 1: age, SEVR, systolic BP, diastolic BP, eGDR, WHR, BMI, heart rate, ACEI/ARB use, HDL-cholesterol, non-HDL-cholesterol, smoking history, anti-lipidemic agent use

b

Variables available to Models 2 & 3: Model 1 variables (except age) + hypertension status (BP>130/80 or medication)

c

Microalbuminuria vs. Normoalbuminuria

Abbreviations: SEVR, subendocardial viability ratio; eGDR, estimated glucose disposal rate; ACEI/ARB, ACE inhibitor/Angiotensin II receptor blocker; BP, blood pressure; BMI, body mass index; WHR, waist-to-hip ratio