TABLE VI.

Calculated Time Delays and Corresponding Cable Lengths for a 7- mm Transmit Focus

Element # Delays (ns) Cable length (m)
1 97.90 21.03
2 90.09 19.35
3 75.74 16.27
4 61.18 13.14
5 46.51 9.99
6 31.27 6.72
7 15.61 3.35
8 0 0