TABLE 1.
Quantification and nPCR Results from DNA Extraction Methods
Method | PicoGreen ng/μl | EBV PCR neat | EBV PCR 1:10 |
---|---|---|---|
QIamp micro kit/forensic filter | 3 (1–4.8) | 4/4 | 4/4 |
QIamp micro kit | 2.4 (0.2–7.08) | 4/4 | 3/4 |
QIamp mini kit | 2.3 (0.49–4.48) | 4/4 | 3/4 |
MEM heat-extraction | 0.4 (0.17–0.53) | 0/4 | 0/4 |
Chelex-lysis | 0.4 (0.04–0.69) | 2/4 | 4/4 |