TABLE 1.

Quantification and nPCR Results from DNA Extraction Methods

Method PicoGreen ng/μl EBV PCR neat EBV PCR 1:10
QIamp micro kit/forensic filter 3 (1–4.8) 4/4 4/4
QIamp micro kit 2.4 (0.2–7.08) 4/4 3/4
QIamp mini kit 2.3 (0.49–4.48) 4/4 3/4
MEM heat-extraction 0.4 (0.17–0.53) 0/4 0/4
Chelex-lysis 0.4 (0.04–0.69) 2/4 4/4