Skip to main content
. 2011 Apr;127(4):642–648. doi: 10.1542/peds.2010-1206

TABLE 4.

Peak Flow Device Technique (N = 67)

Percent (N)
Step
    Set marker to 0 68.2 (45)
    Hold meter upright 90.9 (60)
    Do not block marker movement 86.6 (57)
    Deep breath in with mouth open 84.6 (55)
    Place meter in mouth and close lips tightly around meter 92.5 (62)
    Exhale hard and fast into meter 87.9 (58)
    Check the result 83.6 (56)
    Repeat steps 1–7 two more times 56.9 (37)
Children who performed all steps correctly 23.9 (16)