Skip to main content
. 2011 Mar 19;240(3):139–150. doi: 10.1007/s00232-011-9352-z

Table 1.

Boltzmann parameters

Preparation V j,0 (mV) g j,min z n
Cx43-tag/Cx43-tag −67.0/69.7 (2.5/3.3) 0.35/0.32 (0.02/0.03) −1.15/1.12 (0.09/0.10) 10
wt-Cx43/wt-Cx43a −60.8/62.9 (0.6/0.4) 0.26/0.25 (0.01/0.01) −3.4/2.9 (0.23/0.13) 11
wt-Cx43/Cx43-tag −72.5/70.9 (2.9/2.1) 0.23/0.30 (0.02/0.02) −1.3/2.1 (0.07/0.16) 15
Cx40-tag/Cx40-tag −46.5/47.5 (1.3/1.3) 0.24/0.20 (0.02/0.02) −3.3/3.8 (0.51/0.48) 4
wt-Cx40/wt-Cx40b −55.1/55.9 (1.6/1.1) 0.20/0.19 (0.02/0.01) −1.82/2.3 (0.18/0.20) 13
wt-Cx40/Cx40-tag −124.5/10.2 (11.3/2.1) n.d./0.07 (–/0.01) −0.33/1.8 (0.01/0.18) 5
Cx45-tag/Cx45-tag −43.4/47.0 (0.8/1.2) 0.15/0.12 (0.01/0.02) −2.2/1.8 (0.13/0.13) 9
wt-Cx45/wt-Cx45a −38.9/38.5 (0.7/0.7) 0.17/0.16 (0.01/0.01) −2.5/2.7 (0.18/0.17) 13
wt-Cx45/Cx45-tag −71.9/17.4 (1.9/2.5) n.d./0.18 (–/0.02) −2.04/1.61 (0.26/0.20) 5

Means ±1 SEM (in parentheses)

aData taken from Desplantez et al. (2004)

bData taken from Desplantez et al. (2007). For experiments on mixed channels, see electronic supplement

V j,0, V j at which g j,ss is half-maximally inactivated; g j,min, minimal conductance at large V j; z, equivalent number of unitary positive charges q moving through the electric field applied; n, number of cell pairs; n.d., not determined

P values (V j,0, g j,min, z): <0.05, <0.05, <0.0001 (homotypic Cx43); <0.0001, >0.05, <0.05 (homotypic Cx40); <0.0001, >0.05, <0.05 (homotypic Cx45)