Skip to main content
. 2010 Dec 30;4:176–179. doi: 10.2174/1874613601004010176

Table 1.

Results of Follow-Up Testing of INSTITM Non-Reactive or Indeterminate Early HIV Sero-Conversion Specimens

Case # Initial Specimensa Follow-Up Specimensb
Siemens ADVIA Centaur EIA (Signal/Cutoff) Siemens ADVIA Centaur EIA Result INSTITM Result Siemens ADVIA Centaur EIA Result INSTITM Result Days From Initial to INSTITM Reactive Followup Specimend
3 0.8 NR NR R R 49
6 0.8 NR NR R R 251
18 <0.05 NR NR R R 16
33 <0.05 NR NR R R 15
2 1.9 R Indet NT R 29
4 23.2 R Indet R R 88
29 18.5 R Indet R R 16
30 17.3 R Indet R R 13
51 1.0 R Indet NT R 20
7 4.0 R NR R NSQ
9 10.4 R NR R R 42
11 8.1 R NR R R 73
21 >50 R NR R R 26
25 1.3 R NR R NSQ
31 41.0 R NR R R 8
37 13.8 R NR R R 8
49 2.5 R NR R R 22
57 1.2 R NR R Rc 12
60 3.3 R NR R R 7

NR=non-reactive; R=reactive; Indet=indeterminate; NSQ=insufficient quantity; NT=not tested.

a

All specimens were HIV-1 p24 antigen confirmed reactive.

b

All specimens were HIV-1 Western Blot positive.

c

A follow-up specimen collected 7 days after the initial specimen was INSTITM indeterminate.

d

Mean and median times from initial to INSTITM reactive follow-up specimen are 41 and 20 days, respectively.