Skip to main content
. 2011 Mar 20;6:4. doi: 10.1186/1748-7161-6-4

Table 1.

Protocol of the Lyon Brace

Cobb Magnitude Nb and time in the plaster cast Wearing of the Lyon brace Time to begin Weaning
< 30° 1 cast -1 month nightly End of height growth

30-40° 2 casts - 1 month each After school 16 h/24 1 year after the end of height growth

> 40° 2 casts - 2 months each 23 h/24 2 years after the end of height growth

The protocol depends on the angle of the scoliosis